Patent Radar / Organ-on-Chip Measurement Systems · Application publication

Patterning impedance electrodes directly on a porous barrier membrane

The application places the electrodes on the substrate where barrier cells grow. Described tests compare resistance with cell-free controls at several frequencies.

Original title: MICROFLUIDIC POROUS MEMBRANE ELECTRICAL CELL-SUBSTRATE IMPEDANCE SENSING

THE GOVERNING COUNCIL OF THE UNIVERSITY OF TORONTO

US20250013155A1 · Published Jan 9, 2025

Read original disclosure

On-chip measurement problem

Disclosure: The description identifies electrode impedance as a contribution that can obscure electrical cell-substrate impedance sensing on porous supports. [background-impedance]

Approach disclosed

Claim context: Claim 1 bonds a conductive sheet to a porous membrane and patterns the electrode by photolithographic etching. [electrode-method]

Signals, calibration & endpoints

Direct sensor or sampling readout

Electrical resistance response at specified frequencies

Disclosure: The described tests record the response at several frequencies in cultured and cell-free devices. [normalized-wells]

units

Not located in the cited passages

Calibration or signal analysis

Normalize against a cell-free device

Disclosure: The reported analysis uses resistance from a cell-free device as the normalization reference. [normalized-wells]

Estimated endpoint

Normalized resistance of the cultured barrier

Disclosure: The electrical metric is used to study the barrier and can be compared with a separate permeability assay. [normalized-wells] [permeability]

units

Not located in the cited passages

Reference measurement

Further source checks pending

Control action

Further source checks pending

Chip, sensing location and endpoint

model system and compartment

Disclosure: The membrane supports endothelial or epithelial cells. With electrodes on the growth surface, the signal comes from the cell-substrate interface. [barrier-model] [ecis-location]

chip geometry and sensing location

Disclosure: The description places working and counter electrodes on a biocompatible porous membrane and specifies a range of microchannel dimensions. [microfluidic-electrode]

readout reference and endpoint

Disclosure: The description normalizes resistance to cell-free controls at 400 Hz, 4 kHz and 40 kHz in a well-plate test. It separately describes comparing brain endothelial monolayer resistance with dextran permeability. [normalized-wells] [permeability]

More measurement context

chip measurement relevance

Disclosure: The application changes the sensing geometry at the porous membrane of a barrier model and describes a cell-free reference for the impedance measurement. [electrode-method] [background-impedance]

flow and environment

Further source checks pending

disturbance and model limits

Further source checks pending

Source-stated contribution & selected claim context

Further source checks pending

Reported performance

Further source checks pending

Evidence in the cited disclosure

Disclosure only

Limitations & open questions

AI interpretation: The normalization example uses wells. A perfused chip can have a different electrode geometry, medium and baseline; the reported comparison does not establish transfer to that geometry. [normalized-wells] [microfluidic-electrode]

Further source checks pending

Document & family context

Family grouping unresolved.

Legal status not assessed.

Draft provenance

AI summary of cited USPTO claims and description. Each citation identifies the source publication and XML locator. Applicant names match the USPTO application front page and weekly XML.

AI draft published Nov 8, 2026 · Added Nov 8, 2026 · Updated Nov 8, 2026

The draft covers the cited claims and description. Figures and performance beyond those passages are outside its scope.

Source: United States Patent and Trademark Office, Open Data Portal, US20250013155A1.

Report a correction · pr-f17b391dd3ab887d
All Patent Radar