Methods Radar

Detecting phosphate plastic additives with an amphiphilic catalyst

A nanoparticle interface concentrates additives near a phosphatase-like catalytic domain.

Angewandte Chemie International Edition · Published Nov 20, 2026 · AI summarized · Based on the abstract

The research question

How can hydrophobic phosphate additives be assayed directly in water?

What is new

The surface design links enrichment and catalytic detection while reducing competition for the catalytic sites.

How it works

An amphiphilic surface enriches target compounds near platinum hydroxyl sites that provide a catalytic colorimetric readout.

What it measures

Colorimetric responses to phosphate ester additives.

Sample context

Aqueous tests and samples containing additives leached from plastics.

Evidence in this paper

The authors demonstrate qualitative and quantitative measurements in real samples and report improved catalytic efficiency relative to their comparison systems.

Limitations

  • Mixtures, other hydrolyzable compounds and sample color can affect the response. Individual additives may require separate calibration.

Practical considerations

  • Use matrix blanks and independently measured standards to assess interference and recovery.

Evidence sources

  • The authors demonstrate qualitative and quantitative measurements in real samples and report improved catalytic efficiency relative to their comparison systems. Abstract

Explore in the Atlas

A dedicated Atlas card for this method has not yet been added.

Original article

Yinjun Tang et al.. Amphiphilic Interface‐Mediated Dual‐Domain Architecture Enhances Phosphatase‐Like Activity for Plastic Additives Assay. Angewandte Chemie International Edition. 2026-11-20.

10.1002/anie.2745660